PERENCANAAN PERKUATAN STRUKTUR GEDUNG KANTOR CAMAT PETANG AKIBAT PENAMBAHAN LANTAI DENGAN FRP (FIBER REINFORCED POLYMER)

  • I Putu Pandu Rusmana Universitas Warmadewa
  • I Gst. Nym. Putra Wijaya Universitas Warmadewa
  • I Made Ardantha Universitas Warmadewa

Abstract

The existing building consisting of 3 floors if 3 floors is added will result in the existing structure not being able to withstand the workload due to the addition of the 3 floors so that the structure is needed. Structural reinforcement that is easily applied to reinforced concrete structures, one of which is FRP (fiber reinforcement polymer) which has a tensile strength of 7-10 higher than the tensile strength of reinforcing steel. In the office structure of the evening subdistrict after the addition of 3 floors there were several structural components that were not strong enough to withstand the added burden of B1 and B1A Beams on the pedestal which were 26 stems and 49 stems. The structure of the K1 column due to the addition of the floor also experiences an inadequacy in holding the load as much as 45 stems. Beams B1, B1A, and Column K1 performed structural reinforcement with FRP (fiber reinforcement polymer) with the following dimensions: Beams B1 and B1A reinforced with FRP tensile strength of 3400 MPa, FRP thickness of 1 mm, FRP width of 100 mm and FRP number the one used is 1 layer. The K1 column was strengthened with FRP tensile strength of 2100 MPa, FRP thickness of 0.5 mm, FRP width of 100 mm and the number of FRP used was 1 coil.

References

ACI Committee 440. 2002. Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures. ACI 440.2R-02.

Asroni, A. (2010). Balok dan Pelat Beton Bertulang Edisi Pertama. Yogyakarta: Graha Ilmu.

Asroni, A. (2010). Kolom, Fondasi dan Balok "T" Beton Bertulang Edisi pertama. Yogyakarta: Graha Ilmu.

Badan Standardisasi Nasional. (2012). SNI 1726:2012 Tata Cara Perencanaan Ketahanan Gempa untuk Struktur Gedung dan Non Gedung. Badan Standardisasi Nasional.

Badan Standardisasi Nasional. (2013). SNI 1727:2013 Beban Minimum untuk Perancangan Bangunan Gedung dan Struktur Lain. Badan Standardisasi Nasional.

Badan Standardisasi Nasional. (2013). SNI 2847-2013 Persyaratan Beton Struktural Untuk Bangunan Gedung. Badan Standardisasi Nasional.

Christiawan, I., Triwiyono, A., Christady, H. Januari 2008. Evaluasi Kinerja dan Perkuatan Struktur Gedung Guna Alih Fungsi Bangunan. Forum Teknik Sipil No.XVIII/ 1-Januari 2008. http://puslit2.petra.ac.id/ejournal/index.php/cef/, diunduh 9 April 2017.

Christiawan, I. April 2009. Perkuatan (Strengthening) Struktur Beton Dengan Fiber Reinforced Polymer (FRP), Vol. 6, No. 01 (2009). https://ejournal.undip.ac.id/index.php/metana/article/view/1797 , diunduh 17 April 2018.

Departemen Pekerjaan Umum, 1983, â€Peraturan Pembebanan Indonesia Untuk Gedung 1983†(PPIUG 1983), Bandung.

Sami, Y. 2008. Strengthening of Fire-damage RC Columns using CFRP Fabrics. C:UsersI MADE ARDI WIGUNADownloadsDocumentsYaman Sami Shareef Al-Kamaki Thesis.pdf, diunduh 18 April.

Sulistiawan, A., Soehardjono, A., Tavio. September 2012. Retrovit Kolom Pendek Beton Bertulang Persegi Dengan Perkuatan Eksternal Carbon Fiber-Reinforced Polymer Di Bawah Pengaruh Pembebanan Siklik. Teknologi Dan Kejuruan, Vol. 35, No. 2, September 2012:201-212. http://download.portalgaruda.org/article.php?article=137587&val=407, diunduh 17 April 2018.

Published
2019-01-24
Section
Articles
Abstract viewed = 456 times
PDF (Bahasa Indonesia) downloaded = 829 times