Composite structure in the Kutus-kutus factory building, Gianyar, Bali

  • Ni Putu Indah Puspita Anggraeni Department of Civil Engineering, Warmadewa University, Denpasar, 80235, Indonesia
  • I Nengah Sinarta Master Program of Infrastructure and Environmental Engineering, Warmadewa University, Denpasar, 80235, Indonesia
  • I Putu Ellsa Sarassantika Department of Civil Engineering, Warmadewa University, Denpasar, 80235, Indonesia
Keywords: composite, dynamic analysis, shear connector, structure

Abstract

This study focuses on the design implementation and performance analysis of concrete-steel composite structure of a four-story Kutus-Kutus Factory, a facility for the production of herbal oils, built in the seismically active Gianyar district of Bali. In order to create an efficient, fully composite cross section, the design process uses an analytical approach that emphasizes the relationship between the concrete slab and steel beams as well as the design of each of these components. The structure was designed and assessed in accordance with Indonesia Building Standard guidelines for minimum load, earthquake-resistant, and concrete and steel based material requirements. The final results of the design confirmed that the composite performance is strong enough to withstand enormous loads combined in industrial buildings, particularly in seismically active areas, and can operate within the recommended safety margins and restrictions. This paper ends with a call for more research on the real application of composite structure design in Indonesia, which can then assist the rapidly expanding Indonesian construction industry in maximizing the advantages of using composite construction techniques.

References

C. B. Casita, I. P. E. Sarassantika, and R. Sulaksitaningrum, “Behaviour of Rectangular Concrete Filled Tubes and Circular Concrete Filled Tubes under Axial Load,†J. Appl. Sci. Manag. Eng. Technol., vol. 1, no. 1, pp. 14–20, 2020.

I. W. M. Andreasnata, I. N. Sinarta, N. K. Armaeni, and I. P. E. Sarassantika, “Column structure strengthening with FRP (Fiber Reinforced Polymer) due to story addition,†J. Infrastrcuture Plan. Engfineering, vol. 1, no. 1, pp. 38–45, 2022.

H. L. Hsu, J. C. Hsieh, and J. L. Juang, “Seismic performance of steel-encased composite members with strengthening cross-inclined bars,†J. Constr. Steel Res., vol. 60, no. 11, pp. 1663–1679, 2004.

C. FD, “Perencanaan alternatif struktur komposit hotel neo condotel kota batu,†2018.

A. W. Mulifandi, M. T. Hidayat, and D. Setyowulan, “Perencanaan Alternatif Struktur Komposit Gedung Volendam Holland Park Condotel Di Kota Batu,†J. Mhs. Jur. Tek. Sipil, vol. 1, no. 2, p. pp.938-947, 2017.

Fajar, “Studi Altenatif Perencanaan Struktur Komposit pada Gedung Mall Dinoyo,†vol. 3, no. 2, pp. 100–112, 2015.

W. K. Hong et al., “Composite beam composed of steel and precast concrete (modularized hybrid system). Part IV: Application for multi-residential housing,†Struct. Des. Tall Spec. Build., vol. 19, no. 7, pp. 707–727, 2010.

J. Nie, J. Wang, S. Gou, Y. Zhu, and J. Fan, “Technological development and engineering applications of novel steel-concrete composite structures,†Front. Struct. Civ. Eng., vol. 13, no. 1, pp. 1–14, 2019.

2020 SNI 1727, “Beban desain minimum dan Kriteria terkait untuk bangunan gedung dan struktur lain 1727:2020,†Badan Standarisasi Nas. 17272020, no. 8, pp. 1–336, 2020.

Badan Standardisasi Nasional, “Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung dan Non Gedung,†Sni 17262019, no. 8, p. 254, 2019.

B. S. N. (BSN), “Persyaratan Beton Struktural untuk Bangunan Gedung dan Penjelasan (SNI 2847:2019),†Standar Nas. Indones., no. 8, pp. 653–659, 2019.

Badan Standardisasi Nasional, “Penetapan Standar Nasional Indonesia 1729 : 2020 Beban Desain Minimum dan Kriteria Terkait Untuk Bangunan Gedung dan Struktur,†Badan Standarisasi Nas. 17292020, no. 8, pp. 1–336, 2020.

SteelConstruction.info, “Design of composite steel deck floors for fire - SteelConstruction.info,†2019. .

Computer and Structures.Inc (CSI), “ETABS.†Computer and Structures, Inc (CSI), 2013.

I. N. Sinarta and I. M. B. Pinandika, “Comparison Of Pushover Method And Direct Displacement Method In Earthquake Load Analysis With Performance-Based Design Concepts,†Ukarst Univ. Kadiri Ris. Tek. Sipil, vol. 4, no. 2, 2020.

Published
2022-10-25
Section
Articles
Abstract viewed = 132 times
PDF downloaded = 124 times